You only need to configure the base station that you want to use as the master. The other base stations assigned to the DECT system are automatically detected.
|
|
A factory reset must be performed on the base station that you want to configure as master, see Perform factory reset.
|
|
The master base station receives the AirSync role.
Therefore, place the base station centrally and within range of all other base stations in the DECT system.
|
|
To open the administration web interface within the local network, you can also use the following line in the browser instead of the IP address of the base station: https://<Base station model>-<last three bytes of the MAC address>.
e.g. http://ipbs3-28-07-bb
The corresponding data can be found on the white label on the bottom of the base station.
|
|
If you cannot open the configuration wizard, perform a factory reset, see Perform factory reset
|