Certified SIP end devices are not supported in the standby scenario (SwyxStandby): Certified SIP devices cannot log on to the standby server. If Desk Phones are processed on the standby system, this may result in disturbances on the master system.
|
|
For the provisioning of the Desk Phones it is necessary that the IP address of the SwyxServer can be resolved in the local network. If no name resolving services (DNS) run in your network, enter the current IP address of the SwyxServer in the Windows Registry on the computer on which SwyxServer is installed. (HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Swyx\General\CurrentVersion\Options\LocalIPAddress)
|
|
If the provisioning of phones cannot be performed via multicast due to the network infrastructure, you can also distribute the provisioning URL (e. g. http://172.20.1.1:9200/ippbx/client/v1.0/deviceprovisioning/) via DHCP Option 66.
|
|
The setting options on menu pages and in configuration wizards depend on your administration profile and your SwyxWare solution.
|